MonitorWare Agent Event ID 11225: RELP listener shutdown wake fallback#
Answer#
The immediate local wake could not be delivered, so shutdown uses the bounded listener fallback.
Event details#
Event ID:
11225Severity: Warning
Component: RELP listener
Windows Event Log source:
AdisconMonitoreWareAgentAvailable since: 26.08
Message pattern: The RELP listener loopback wake failed; shutdown is using the bounded external-library fallback. Additional detail: {event_detail}
Possible causes#
Local socket creation or loopback connection failed because of resource pressure or address-family configuration.
Immediate checks#
Check local socket resource usage and the configured RELP listener address and port.
Detailed procedures#
Verify listener binding and Windows Firewall rules — Confirm effective address, port, transport, owning process, and inbound policy.
Collect an Event ID and neighboring product events — Preserve the complete event and the product events immediately before and after it.
Export configuration and collect a bounded debug log — Create a text configuration export and time-bounded debug capture, then disable debugging.
Verify the result#
Stop an idle RELP listener and confirm that Event ID 11225 does not recur and shutdown completes promptly.
Evidence to collect#
The complete Windows Application Event Log entry.
The RELP listener address family, bind address, port, and debug log.
Escalation#
If the event continues after the detailed procedures, collect the listed evidence and contact Adiscon Support.